PEARL Inspect and Test Standards provide inspection, cleaning, testing, and documentation instructions and guidelines that when followed by trained technicians will provide evidence that an electrical device is free of inherent flaws or faults.
The PEARL Inspect and Test Standard is neither a reconditioning standard, nor does it promise extended service life or improve reliablity. It is intended to indicate that the equipment or device in its present state shows no indication of damage and tests satisfactorily to manufacturer or industry operational specifications.
PEARL member companies affix the green PEARL Inspected & Tested Seal to electrical equipment that has passed the PEARL
Inspect & Test Standards.
Organized by type of equipment or apparatus, you can view and/or download any of the individual PEARL Inspect & Test Standards in PDF file format by using the links below.
Section 1100 Low Voltage Disconnect Switches
• 1110 Low Voltage Disconnect Switches Manually Operated Air Non-Fusible
• 1114 Low Voltage Disconnect Switches Manually Operated Air Fusible
• 1130 Low Voltage Disconnect Switches Manual Trip Power Non-Fusible
• 1134 Low Voltage Disconnect Switches Manual Trip Power Fusible
• 1140 Low Voltage Disconnect Switches Electric Trip Power Non-Fusible
• 1144 Low Voltage Disconnect Switches Electric Trip Power Fusible
• 1150 Low Voltage Safety Switches Single Throw Non-Fusible
• 1154 Low Voltage Safety Switches Single Throw Fusible
• 1170 Low Voltage Disconnect Switches Panelboard Non-Fusible
• 1174 Low Voltage Disconnect Switches Panelboard Fusible
• 1180 Low Voltage Safety Switches Double Throw Non-Fusible
• 1184 Low Voltage Safety Switches Double Throw Fusible
Section 1200 Low Voltage Circuit Breakers
• 1211 Low Voltage Molded Case Circuit Breaker with Thermal Magnetic Trip Unit
• 1212 Low Voltage Molded Case Circuit Breaker with Solid State Trip Unit
• 1214 Low Voltage Molded Case Switches (Non-Automatic Circuit Interrupters)
• 1215 Low Voltage Molded Case Motor Circuit Protectors
• 1221 Low Voltage Insulated Case Circuit Breakers with Solid State Trip Unit
• 1231 Low Voltage Power Circuit Breakers with Series Trip Unit
• 1236 Low Voltage Power Circuit Breakers with Solid State Trip Unit
Section 1300 Low Voltage Panelboards, Switchboards & Switchgear
• 1310 Low Voltage Circuit Breaker Panelboards
• 1320 Low Voltage Switchboards and Switchgear
• 1330 Low Voltage Motor Control Centers
Section 1400 Low Voltage Transformers
• 1410 Low Voltage Transformers Dry-Type (600V AC Max. Primary)
• 1420 Low Voltage Transformers Control Power
• 1430 Low Voltage Transformers Instrumentation Voltage
• 1440 Low Voltage Transformers Instrumentation Current
Section 1500 Low Voltage Motor Control Center Buckets & Enclosed Assemblies
• 1510 Low Voltage Motor Control Center Bucket
• 1520 Low Voltage Magnetic Starters Enclosed
• 1530 Low Voltage Magnetic Starters Combination
Section 1600 Low Voltage Motor Starters
• 1620 Low Voltage Magnetic Starters Open
Section 1700 Protection Relays
• 1710 Instantaneous Overcurrent Relay Electromagnetic Attraction
• 1715 Instantaneous Overcurrent Relay Solid State
• 1720 Time Overcurrent Relay Electromagnetic Induction Disk
• 1730 Instantaneous Voltage Electromagnetic Attraction
• 1735 Instantaneous Voltage Solid State
• 1740 Overvoltage Electromagnetic Relay
• 1750 Low Voltage Thermal Overload Relay
• 1760 Low Voltage Solid State Overload Relay
• 1765 Low Voltage Solid State Overload Relay Multi Function
Section 1800 Low Voltage Contactors and Relays
• 1810 Low Voltage AC Contactor
• 1820 Low Voltage AC Control Relay No Time Delay
• 1825 Low Voltage AC Control Relay Time Delay
• 1830 Low Voltage DC Contactor
• 1840 Low Voltage DC Control Relay No Time Delay
• 1845 Low Voltage DC Control Relay Time Delay
Section 1900 Apparatus Accessories
• 1930 Low Voltage Surge Arrestors
Section 2000 Low Voltage Bus Duct
• 2010 Low Voltage Bus Duct Plug-In Type
• 2020 Low Voltage Bus Duct Feeder Type
• 2030 Low Voltage Disconnect Switches Bus Duct Plug-in Non-Fusible
• 2035 Low Voltage Disconnect Switches Bus Duct Plug-in Fusible
• 2040 Low Voltage Molded Case Circuit Breaker Bus Duct Plug-in
• 2050 Low Voltage Molded Case Switch Bus Duct Plug-In
Section 2100 Medium Voltage Disconnect Switches
• 2110 Medium Voltage Air Disconnect Switches Enclosed Manually Operated Non-Fusible
• 2111 Medium Voltage Air Disconnect Switches Enclosed Manually Operated Fusible
• 2120 Medium Voltage Air Disconnect Switches Enclosed Electrically Operated Non-Fusible
• 2121 Medium Voltage Air Disconnect Switches Enclosed Electrically Operated Fusible
• 2130 Medium Voltage Vacuum Disconnect Switches Manually Operated Non-Fusible
• 2131 Medium Voltage Vacuum Disconnect Switches Manually Operated Fusible
• 2140 Medium Voltage Vacuum Disconnect Switches Electrically Operated Non-Fusible
• 2141 Medium Voltage Vacuum Disconnect Switches Electrically Operated Fusible
Section 2200 Medium Voltage Circuit Breakers & Starters
• 2210 Medium Voltage Circuit Breakers Air
• 2220 Medium Voltage Circuit Breakers Vacuum
• 2230 SF6 Circuit Breaker – Stored Energy-Spring
• 2250 Medium Voltage Contactors Air
• 2260 Medium Voltage Contactors Vacuum
Section 3100 Low Voltage & Medium Voltage Fuses
• 3110 Low Voltage & Medium Voltage Fuses – Non-Refill Style
• 3120 Low Voltage & Medium Voltage Fuses – Refill Style
Section 4100 Low Voltage Wire & Cable
• 4110 Low Voltage Wire and Cable Unshielded – Single Conductor
• 4115 Low Voltage Wire and Cable Unshielded – Multiple Conductors
• 4120 Low Voltage Wire and Cable Shielded – Single Conductor
• 4125 Low Voltage Wire and Cable Shielded – Multiple Conductors
Section 4200 Medium Voltage Wire & Cable
• 4210 Medium Voltage Wire and Cable Unshielded – Single Conductor
• 4215 Medium Voltage Wire and Cable Unshielded – Multiple Conductors
• 4220 Medium Voltage Wire and Cable Shielded – Single Conductor
• 4225 Medium Voltage Wire and Cable Shielded – Multiple Conductors
Section 6000 Tables
• 6001 Table 1 - U.S. Standard Bus Connection Bolt Torque Values
• 6002 Table 2 - Insulation Resistance Test Values for Electrical Apparatus
• 6003 Table 3 - Molded Case Circuit Breaker Inverse Time Trip Test Values
• 6004 Table 4 - Adjustable Trip Circuit Breaker Instantaneous Trip Setting Tolerances
• 6005 Table 5 - Overpotential Test Voltages for Non-Inductive Electrical Apparatus
• 6006 Table 6 - Transformer Insulation Resistance Test Values
• 6007 Table 7 - Power Factor/Dissipation Factor Recommended Test Voltage Values
• 6008 Table 8 - Maximum Allowable Vibration Amplitude Test Values
• 6009 Table 9 - Wire and Cable Insulation Resistance Test Values
• 6010 Table 10 - Medium Voltage Wire and Cable Maximum Test Voltage Values
• 6011 Table 11 - Insulation Resistance Test Temperature Conversion to 20° C Values
Sample Test Reports
• Standard 1410-I sample test report for low voltage dry type transformers
• Standard 1114 sample test report for low voltage, manually operated, fusible, air disconnect switches.
Section Separators
• Table of Contents
• 1100 Low Voltage Disconnect Switches
• 1200 Low Voltage Circuit Breakers
• 1300 Low Voltage Panelboards, Switchboards & Switchgear
• 1400 Low Voltage Transformers
• 1500 Low Voltage Motor Control Center Buckets & Enclosed Assemblies
• 1600 Low Voltage Motor Starters
• 1700 Protection Relays
• 1800 Low Voltage Contactors and Relays
• 1900 Apparatus Accessories
• 2000 Low Voltage Bus Duct
• 2100 Medium Voltage Disconnect Switches
• 2200 Medium Voltage Circuit Breakers & Starters
• 2300 Medium Voltage Switchgear
• 2400 Medium Voltage Transformers
• 3100 Low & Medium Voltage Fuses
• 4100 Low Voltage Wire & Cable
• 4200 Medium Voltage Wire & Cable
• 6000 Tables
Link to:
• Technical Standards overview
• Reconditioning Standards